GRAFTJACKET NOW™

Tuesday, May 5th, 2015

OSTEOSET™ Resorbable Mini-Bead Kit

Thursday, April 30th, 2015

Address individual patient pathology with a completely resorbable option. Mix and customize calcium sulfate beads in 3.0 and 4.8mm sizes.

PRO-STIM™

Thursday, April 30th, 2015

pro-stim-accelerate-healingPRO-STIM® Injectable Inductive Graft is the next step in composite grafting technology. Built on the PRO-DENSE® material platform as a combination of calcium sulfate and calcium phosphate, PRO-STIM® graft adds demineralized bone matrix (DBM) for osteoinductive factors to speed the healing and remodeling process.

Pre-Clinical In-Vivo Testing

In an early timepoint study of PRO-STIM® graft and autograft materials in a critical sized defect, PRO-STIM® graft was associated with accelerated healing, earlier initiation of remodeling, and greater maximum bone volume during healing compared to autograft.*

Accelerated Healing versus Autograft

Amount (Area Fraction) of New Bone

pro-stim-graph

Over a year of clinical performance in challenging applications

Surgeon Observations

“PRO-STIM® graft gives the surgeon a viable alternative to autograft without the complications associated with the donor site. This option provides a proven, flowable, composite bone graft that adds DBM to enhance healing and remodeling into native bone. This setting material has been useful in my orthopaedic practice for both open and percutaneous applications such as bone cysts and core decompressions.”
Michael D. Neel, MD, OrthoMemphis, Memphis, TN

Ordering Information

86SR-0404 PRO-STIM® EXTREMITY 4CC
86SR-0410 PRO-STIM® 10CC
86SR-0420 PRO-STIM® 20CC
86SR-CK15 PRO-STIM® CORE DECOMPRESSION KIT

 *Canine proximal humerus model: Accelerated healing compared to autograft –Compared to autograft, PRO-STIM® Graft showed accelerated new bone formation at 13 and 26 weeks. This was evident by the slightly higher average stiffness, the greater amount of average new bone formation, and statistically significantly greater compressive strength shown for PRO-STIM® Graft treated defects. By comparing the 26-week clinical and contact radiographs and gross cross-sectional images and histological images, there appeared to be little to no apparent difference between defects filled with either PRO-STIM® Graft or autograft. Comparison of percentage of new bone, compressive strength, and modulus of elasticity showed no statistically significant differences between the materials at 26 weeks. Data on file at Wright. It is unknown how results from the canine model compare with clinical results in humans.

IGNITE™

Thursday, April 30th, 2015

A low morbidity, time-saving, percutaneous treatment for stable diaphyseal fractures has been advanced to include an increased level of proteins to couple with harvested osteoprogenitor cells from bone marrow.

IGNITE™ Power Mix provides this powerful combination in the form of a minimally invasive graft with osteoconductive, osteoinductive, and osteogenic capacity.

The combination of DBM and BMA has over a decade of clinical evaluation. This composite has demonstrated clinical success comparable to open, autologous grafting in a series of 69 stable nonunions. 1

1. Wilkins RM, et al. Percutaneous treatment of long bone nonunions: The use of autologous bone marrow and allograft bone matrix. WMT publication, 2002.

fracture_healing
ignite_syringe

FUSIONFLEX™

Thursday, April 30th, 2015

Versatile Repair Scaffold Supporting Bone Regeneration

  • Absorbant Medium for Intraoperative Flexibility
  • Compressible and Flexible to Fill Defects of any Shape or Size
  • Versatile Scaffold for Extremity Fusion Procedures

ALLOPURE™ Allograft Bone Wedges

Thursday, April 30th, 2015

As the leader in foot and ankle surgery, Wright continues to develop cutting edge technologies which help simplify complex surgeries with a goal to improve outcomes. ALLOPURE® Allograft Bone Wedges provide Foot and Ankle surgeons the simplicity pulling ready-to-use allograft off the shelf for Evans and Cotton Osteotomies.

Human Allograft

ALLOPURE® Cancellous Wedges

  • RTI Human bone is pre-processed with the BioCleanse® cleaning process and terminally sterilized with either gamma irradiation or gas plasma.
  • Ready-to-Use Cotton and Evans osteotomy configurations with minimal sizing required.
  • Use with the Evans Instrument kit to achieve an 8mm, 10mm, or 12mm wedge.

ALLOPURE® Bicortical Wedges

AlloSource® human bone pre-processed with AlloTrue® cleaning process and terminally sterilized with gamma irradiation.

  • Lifelink human bone pre-processed with Allowash® cleaning process and terminally sterilized with gamma irradiation.
  • Pre-sized and designed for Evans and Cotton osteotomies.
  • Two-sided cortical rim provides natural strength.

 

ALLOPURE® Tricortical Blocks

  • Tricortical bone grafts can be used in a variety of orthopedic applications such as: Lapidus, Cotton, Evans, & other procedures requiring superior strength.
  • Three cortical sides provide structure, strength, and stability.
  • The rough cortical sides resists migration while the porous scaffold provides optimal surface area for osteoconduction.

ALLOMATRIX™ CUSTOM Versatile Bone Putty with Large Cancellous Chips

Thursday, April 30th, 2015

Address Individual Patient Pathology In A Way No Pre-Mixed Putty Can.

Raw Flexibility To Meet Individual Patient Pathology Needs.

Surgeons desire the independence and flexibility to custom blend graft materials to control structural consistency. ALLOMATRIX™ CUSTOM Bone Graft Putty delivers. With features that include a reliable DBM, a carrier medium, and the ability to reconstitute in the OR, ALLOMATRIX™ CUSTOM Bone Graft Putty meets individual patient bone grafting needs in a way no pre-mixed putty can.

Maximum Cancellous Chip Content – Your Choice.

ALLOMATRIX™ CUSTOM Bone Graft Putty incorporates Demineralized Bone Matrix (DBM) and the highest cancellous chip content on the market – both recovered from the same donor, which is blended at the time of surgery. The result is a custom product that can range from minimum to maximum structural consistency. ALLOMATRIX™ CUSTOM Putty provides flexibility to augment the graft with bone marrow aspirate or platelet concentrate without compromising handling characteristics.

Mixability for Maximum Flexibility

  • Bone Marrow Aspirate.
    Add Osteogenic Capacity
  • Platelet Concentrate.
    Add Growth Factors
  • Control Cancellous Chip Content.
    Dial-in Desired Consistency for Custom Applications.